Engine Control System - 2.7L
>>
CVVT Oil Control Valve (OCV)
>>
Repair procedures
>>
Inspection
Repair procedures: Inspection
Turn the ignition switch OFF.
Disconnect the OCV connector.
Measure resistance between the OCV terminals 1 and 2.
Check that the resistance is within the specification. Refer to "