Control Circuit Inspection
■ Check shorted to battery in harness
- Ignition "OFF"
- Disconnect Hub Solenoid Valve and TCCM main harness connector.
- Ignition "ON"
- Measure voltage between Control terminal of Hub Solenoid Valve harness connector and chassis ground.
- Is the measured voltage within specification?
YES
- Go to Next procedure.
NO
- Check for short to battery in harness.
- Repair as necessary and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.
Specification : 0V
■ Check for open in harness
- Ignition "OFF"
- Disconnect Hub Solenoid Valve and TCCM main harness connector.
- Measure resistance between Control terminal of Hub Solenoid Valve harness connector and Control terminal of TCCM harness connector.
- Is the measured resistance within specification?
YES
- Check for shorted to battery in harness.
NO
- Check for open in harness.
- Repair as necessary and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.
Specification : 1Ω below