Replacement Of Component Parts
When replacing the system component parts, supply the following amount of oil to the component parts to be installed.
AMOUNT OF OIL COMPONENT PARTS REFERENCE CHART
| Component parts to be installed | Amount of Oil |
|---|---|
| Evaporator | 50 cc (1.70 fl.oz) |
| Condenser | 30 cc (1.02 fl.oz) |
| Receiver/dryer | 30 cc (1.02 fl.oz) |
| Refrigerant line (One piece) | 10 cc (0.34 fl.oz) |
For compressor replacement, subtract the volume of oil drained from the removed compressor from the specified volume, and drain the calculated volume of oil from the new compressor:
The specified volume-volume of removed compressor = volume to drain from the new compressor.
NOTE:
Even if no oil is drained from the removed compressor, don't drain more than 50cc from new compressor.