ECTS RESISTANCE SPECIFICATIONS

Temperature ECTS Resistance (Ω) Temperature ECTS Resistance (Ω)
(°C) (°F) (°C) (°F)
-20 -4 14.13 ~ 16.83 40 104 1.15
0 32 5.79 60 140 0.59
20 68 2.31 ~ 2.59 80 176 0.32
THERMOSTAT SPECIFICATIONS

Thermostat Normal Parameter
Valve Opening Temp. 82°C (179.6°F)
Valve Closing Temp. 77°C (170.6°F)
Full Open Lift Above 10 mm at 95°C (203°F)