Room Lamps
- The room lamps are can be controlled manually using the 3-state (ON, DOOR, OFF) switch or by the Rear Area Module (RAM). A main switch, located to the left of the steering wheel, is used as a master control switch. The operating logic of the lamps will vary based on the position of the main switch ON, DOOR, or OFF).
- Working conditions
- The functioning depends on the key position in the key cylinder (OFF, ACC, RUN or START)
- When the key goes in RUN or START position while the room lamps are decaying, then the room lamps are turned off immediately.
- When the Ignition key position is RUN or START and the last door is closed then the room lamps are OFF.
- If the room lamps have been activated using the RKE UNLOCK function, and the ignition switch is turned to the RUN or START position, the room lamps will be immediately turned OFF.
- If the Ignition sw status is in RUN or START and Unlock information occurs, then the room lamp status is not changed.
- When the system enters to ARM WAIT mode by Remote Key or Mechanical cylinder lock switches the Room lamp should be turned off immediately.
- If there is RKE Lock signal at any door open, all doors should be locked first and wait for the all door close. No action is taken while the Open Door status is OPEN and the doors are locked. Then when Open Door status changes from OPEN to CLOSE, Room lamps will be OFF immediately.
- The 30sec timer does not depend on the key reminder status.
- If the main switch is changed to ON from DOOR after 20minute lamp OFF, all the lamps are turned ON.
- If the Open Door status changes from OPEN to CLOSE (all doors close) when ignition switch is on RUN position, room lamps and door courtesy lamps should turn off immediately (Do not decay off).
- After 20minute Room Lamp OFF at door open, Room lamps are turned ON again when:
- One of the door open switch's status changes. (Open to Close or Close to Open)
- Ignition key is in RUN or START Position.
- Receiving an UNLOCK event while a door is open and Main Room Lamp Switch is in the DOOR position.
- For the room lamps, when the 20m timer is running and any of the side doors is opened the timer is restarted.
- Functional Diagram
- Truth tableROOM LAMPS TRUTH
Main Room Lamps sw Open Door status (RAM) Luggage interior Lamp (CAN) Room Lamps LS (Door) Room Lamps LS (On) Room Lamp Switch Room Lamp Switch Room Lamp Switch ON DOOR OFF OFF Don't care Don't care OFF OFF OFF OFF OFF ON Don't care Don't care OFF ON ON ON ON DOOR OPEN OFF (*) ON during 20 min then directly OFF OFF ON ON during 20 min OFF OPEN →LOCK (**) ON during 20 min then directly OFF OFF ON during 20 min OPEN →UNLOCK (***) ON during 20 min then directly OFF OFF ON during 20 min CLOSE OFF OFF OFF OFF OPEN → CLOSE Don't care Decayed OFF OFF Decayed OFF OPEN → CLOSE Don't care ON during 20 min then directly OFF OFF ON during 20 min CLOSE →LOCK OFF OFF OFF CLOSE →UNLOCK ON during 30 min then directly OFF OFF ON during 30 min (*): OFF is transmitted when there is no action from Lock/Unlock. It has no impact on the 20mn timer (no restart). (**): LOCK transition is sent by IPM only when door status is CLOSE. Thus there is no action on the 20mn timer in this case. (***): When transition to UNLOCK is received, 20mn timer is restarted.