Hydraulic Pressure Table

Under the constant current amount of VFS (200mA), the line pressure will become as below table. Be sure that the following data can be achieved by specific special facility or device to check the performance of A/T assembly (not on the vehicle), however we can refer the maximum pressure value according to each element.

HYDRAULIC PRESSURE

Solenoid valve Duty (%) Measured Element Pressure kPa (Psi)
LR 2ND UD OD RED*
0 100 0 100 0 LR 1030 ± 20 (149 ± 3)
60 520 ± 40 (75 ± 6)
75 230 ± 40 (33 ± 6)
100 0
100 0 0 100 0 2ND 1030 ± 20 (149 ± 3)
60 550 ± 40 (80 ± 6)
75 220 ± 40 (32 ± 6)
100 0
100 100 0 0 0 OD 1030 ± 20 (149 ± 3)
60 520 ± 40 (75 ± 6)
75 210 ± 40 (30 ± 6)
100 0
100 100 0 0 0 UD 1030 ± 20 (149 ± 3)
60 470 ± 40 (68 ± 6)
75 170 ± 40 (25 ± 6)
100 0
100 0 100 0 100 DIR* 0
75 270 ± 40 (39 ± 6)
60 540 ± 40 (78 ± 6)
0 1030 ± 20 (149 ± 3)

Measuring condition:

  1. PG-A (Input speed): 2,500 RPM
  2. Manual valve position: D
  3. DCC Solenoid duty: 0%