Hydraulic Pressure Table
Under the constant current amount of VFS (200mA), the line pressure will become as below table. Be sure that the following data can be achieved by specific special facility or device to check the performance of A/T assembly (not on the vehicle), however we can refer the maximum pressure value according to each element.
HYDRAULIC PRESSURE
| Solenoid valve Duty (%) | Measured Element | Pressure kPa (Psi) | ||||
|---|---|---|---|---|---|---|
| LR | 2ND | UD | OD | RED* | ||
| 0 | 100 | 0 | 100 | 0 | LR | 1030 ± 20 (149 ± 3) |
| 60 | ↑ | ↑ | ↑ | ↑ | 520 ± 40 (75 ± 6) | |
| 75 | ↑ | ↑ | ↑ | ↑ | 230 ± 40 (33 ± 6) | |
| 100 | ↑ | ↑ | ↑ | ↑ | 0 | |
| 100 | 0 | 0 | 100 | 0 | 2ND | 1030 ± 20 (149 ± 3) |
| ↑ | 60 | ↑ | ↑ | ↑ | 550 ± 40 (80 ± 6) | |
| ↑ | 75 | ↑ | ↑ | ↑ | 220 ± 40 (32 ± 6) | |
| ↑ | 100 | ↑ | ↑ | ↑ | 0 | |
| 100 | 100 | 0 | 0 | 0 | OD | 1030 ± 20 (149 ± 3) |
| ↑ | ↑ | ↑ | 60 | ↑ | 520 ± 40 (75 ± 6) | |
| ↑ | ↑ | ↑ | 75 | ↑ | 210 ± 40 (30 ± 6) | |
| ↑ | ↑ | ↑ | 100 | ↑ | 0 | |
| 100 | 100 | 0 | 0 | 0 | UD | 1030 ± 20 (149 ± 3) |
| ↑ | ↑ | 60 | ↑ | ↑ | 470 ± 40 (68 ± 6) | |
| ↑ | ↑ | 75 | ↑ | ↑ | 170 ± 40 (25 ± 6) | |
| ↑ | ↑ | 100 | ↑ | ↑ | 0 | |
| 100 | 0 | 100 | 0 | 100 | DIR* | 0 |
| 75 | ↑ | ↑ | ↑ | ↑ | 270 ± 40 (39 ± 6) | |
| 60 | ↑ | ↑ | ↑ | ↑ | 540 ± 40 (78 ± 6) | |
| 0 | ↑ | ↑ | ↑ | ↑ | 1030 ± 20 (149 ± 3) | |
Measuring condition:
- PG-A (Input speed): 2,500 RPM
- Manual valve position: D
- DCC Solenoid duty: 0%