Inspection Procedure
- CHECK DTC RELATING TO LINEAR O2 SENSOR
- Connect a Hi-Scan (Pro) to the data link connector.
- Turn the ignition switch ON and monitor any other DTCs relating to linear HO2S.
Are DTCs relating to linear O2 sensor also set?
- No: Go to next step.
- Yes: Do all repairs associated with those codes before proceeding with this procedure.
- CHECK LINEAR O2 SENSOR AND ECM CONNECTORS
Thoroughly check connectors for loose, poor connection, bent, corrosion, contamination, deterioration, or damage. See CONNECTOR INSPECTION PROCEDURE .
Are all connectors good?
- Yes: Go to next step.
- No: Repair or replace it.
- CHECK LINEAR O2 SENSOR
- Thoroughly check the linear O2 sensor for contamination, deterioration or damage.
- Check if the fuel used is unleaded gasoline.
Is linear O2 sensor contaminated, deteriorated or damaged?
- No: Proceed with ECM PROBLEM INSPECTION PROCEDURE .
- Yes: Repair or replace it.