Actuator Checking
ACTUATOR SPECIFICATION
| No. | Items | Forced operation details | Forced operation conditions |
|---|---|---|---|
| 1 | L&R solenoid valve | Operate the solenoid valve using Hi-Scan for five seconds. (Other solenoid valves shall not be energized.) |
|
| 2 | Underdrive solenoid valve | ||
| 3 | Second solenoid valve | ||
| 4 | OD solenoid valve | ||
| 5 | Reduction solenoid valve | ||
| 6 | Damper clutch solenoid valve | ||
| 7 | Auto control relay | Off for 3 seconds | |
| 8 | HIVEC control inhibition | Inhibit until ignition off |