The charging system includes a battery, an generator with a built-in regulator, and the charging indicator light and wire. The generator has eleven built-in diodes (four positive, four negative and three exciter diodes), each rectifying AC current to DC current. Therefore, DC current appears at generator "B" terminal.

In addition, the charging voltage of this generator is regulated by the battery voltage detection system. The generator is regulated by battery voltage detection system. The main components of the generator are the rotor, stator, rectifier, capacitor brushes, bearing and V-ribbed belt pulley. The brush holder contains a built-in electronic voltage regulator.

Fig 1: Illustrating Generator Components
G00320454Courtesy of KIA MOTORS AMERICA, INC.