ETACS Function
- Intermittent wiper
Time specification
T1: Max. 0.3 sec.
T2: 0.7 +/- 0.1 sec. (Time of wiper motor 1 rotation)
T3: (Intermittent time): T2 + FAST (2.0 +/- 0.2 sec.)
T2+SLOW (10 +/- 1.0 sec.)
- Washer related wiper
.
Time specification
T1: 0.6 +/- 0.1 sec.
T2: 2.5 - 3.8 sec.
T3: 0.2 - 0.6 sec.
T4: 0.7 +/- 0.1 sec.
This function should be operated preferentially even though the variable intermittent wiper is operating.
- Rear window defogger and front windshield defogger
.
Courtesy of KIA MOTORS AMERICA, INC.
Time specification
T1: 20+/- 1 min.
- Seat belt warning
Time specification
T1: 6 +/- 1.5 sec.
T2: 0.5 +/- 0.1 sec.
- Ignition key hole illumination
Time specification
T1: 10 +/- 1 sec.
T2: 0 - 10 sec.
- Delayed out room lamp
Time specification
T1: 5 - 6 sec.
T2: 30 +/- 3 sec.
T3: 20 +/- 2 min.
- Ignition key reminder
- Battery saver .
- Power window
Time specification
T1: 30 +/- 3 sec.
- Crash door unlock
Time specification
T1: 200 msec.
T2: 0.5 +/- 0.1 sec.
T3: 60 +/- 2 msec.
- Door ajar
Alarm occurs while the door or tail gate opened when the vehicle speed is 5 km/h over.
- Tail gate glass open
Time specification
T1: 3 +/- 0.5 sec.
T2: 0.5 +/- 0.1 sec.
- Central door lock/unlock .
- 2-Turn unlock
Time specification
T1: 3 +/- 0.5 sec.
T2: 0.5 +/- 0.1 sec.
- Remote keyless Entry system
.
- Door lock
Time specification
T1: 1.0 sec.
- Door unlock
Time specification
T1: 0.5 sec.
- Tail gate glass open
Time specification
T1: 0.5 sec.
- Panic
Time specification
T1: 27 +/- 2 sec.
T2: 0.5 +/- 0.1 sec.
T3: 0.5 +/- 0.1 sec.
T4: 2.7 +/- 0.5 sec.
- Door lock
- Code saving method
- To store transmitter code, first apply the battery voltage to terminal "6" of DLC (Data Link Connector) and then operate as shown in the illustration.
NOTE: Do not disconnect the negative (-) battery terminal.
- Remove the battery voltage and then check the operation of the keyless entry system.