Quarter Glass Switch
Operate switch and check for the specified continuity between the terminals. See QUARTER GLASS SWITCH CONTINUITY . See Fig 1. If the continuity is not as specified, replace the switch.
QUARTER GLASS SWITCH CONTINUITY
| Application | Continuity Between Terminals No. | |
|---|---|---|
| Right | ||
| Open | 1 & 8 | |
| Close | 6 & 8 | |
| Left | ||
| Open | 8 & 12 | |
| Close | 5 & 8 | |