FULLY CLOSED AND LATCHED |
FULLY OPEN |
BETWEEN FULLY OPEN AND CLOSED |
DESCRIPTION |
| PRIMARY RATCHET - AJAR SWITCH CLOSED |
FALSE |
TRUE |
TRUE |
Primary/Ajar switch, internal to the liftgate latch. Open
when latch is in primary. Closed
when latch is out of primary. |
| SECONDARY RATCHET SWITCH CLOSED |
FALSE |
TRUE |
TRUE |
Internal to the liftgate latch. Indicates when the latch is in secondary position. Open
when in secondary position. Closed
when out of secondary position. |
| SECTOR GEAR SWITCH CLOSED |
FALSE |
FALSE |
FALSE |
Internal to the liftgate latch. Essentially a park switch for the latch. When latch is running a cinch or release, this switch is Closed
. After cinch or release is complete, the Power Lift Gate Module (PLGM) will reverse direction of the latch until the switch is Open
. |
| POSITION SENSOR NUMBER 1 AND NUMBER 2 CLOSED |
FALSE OR TRUE |
FALSE OR TRUE |
FALSE OR TRUE |
When in motion, these signals will toggle between Open
and Closed
. The two signals together tell the PLGM the speed and distance of liftgate travel. These inputs are also used by the PLGM to sense obstacles encountered by the liftgate. |
| POSITION SENSOR PULSE COUNTS |
100 |
1600 TO 1800 |
100 TO 1600 |
This is a counter derived from the pulses coming from Position Sensors number 1 and 2. This count represents total travel of the liftgate (to mechanical end of travel). |
| GATE FULL OPEN SWITCH POSITION COUNTS |
ABOUT 1600 |
ABOUT 1600 |
ABOUT 1600 |
This is a counter derived from the pulses coming from Position Sensors number 1 and 2. This count represents the position of the full open switch in the PDU. |
| |
| INPUT |
NORMAL (NOT PRESSED) |
PRESSED |
DESCRIPTION |
| LEFT PINCH SENSOR |
About 4.1 Volts (10 Kilohms) |
Less than 1 Volt |
Pinch sensor reads 10 kilohms when not pinched. When pinched, shorts out the 10 kilohm resistor and should read from 0 to about 200 ohms. |
| RIGHT PINCH SENSOR |
About 1.7 Volts at 21° C (70° F) |
Less than 1 Volt |
Right pinch sensor has a 10 kilohm at room temperature thermistor in place of the resistor. When not pinched, resistance is proportional to the ambient temperature. When pinched, shorts out the thermistor and should read from 0 to about 200 ohms. |
| EXTERIOR HANDLE SWITCH |
5 Volts (Normally Open) |
About 3.4 Volts (4.7 Kilohms) |
Located in the liftgate latch. Open circuit when not active. 4.7 kilohms to ground when handle is activated. |
| OVERHEAD CONSOLE SWITCH |
About 4.7 Volts |
About 3.4 Volts |
When not pressed, should read about 810 kilohms. When pressed, should read about 4.7 kilohms. |
| D-PILLAR (REAR ZONE) SWITCH |
About 4.7 Volts |
About 3.4 Volts |
When not pressed, should read about 810 kilohms. When pressed, should read about 4.7 kilohms. |
| |
| OUTPUT |
DESCRIPTION |
DIAGNOSE |
| HALL EFFECT POWER |
Provides +5 Volts to the Hall sensors in the PDU |
As long as the PLGM is awake it should read approximately +5 volts. |
| LATCH MOTOR |
Provides +/- 12 Volts to latch motor for cinch and release |
Actuate with diagnostic scan tool. Should see positive voltage on the cinch wiring connector terminal for cinch direction. Should see positive voltage on the release wiring connector terminal for release direction. Refer to the appropriate wiring information for specific harness and connector pinout information. |
| DRIVE MOTOR |
Provides +/- 12 Volts to PDU for power Open or Close |
Actuate with diagnostic scan tool. Should see positive voltage on the open wiring connector terminal for open direction. Should see positive voltage on the close wiring connector terminal for close direction. Refer to the appropriate wiring information for specific harness and connector pinout information. |
| CHIME |
Provides signal to output sound |
Actuate with diagnostic scan tool. While monitoring with a digital multimeter some activity should be present, but not much voltage. |