LEMON Manuals: Even more car manuals for everyone
Home >> Jeep >> 2007 >> Liberty Limited, 4WD, Automatic >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System >> Generator >> Installation >> Generator - Diesel

Generator - Diesel

Fig 1: View Of Generator - Diesel
GC0046812Courtesy of CHRYSLER LLC
1 - GENERATOR
2 - MOUNTING BOLTS
  1. Position generator (1) to engine.
  2. Install generator mounting bolts/nuts (2) and tighten to 54 N.m (42 ft. lbs.).
    Fig 2: View Of Generator Support Bracket - Diesel
    GC0046813Courtesy of CHRYSLER LLC
    1 - SUPPORT BRACKET
    2 - SUPPORT BRACKET NUT
    3 - SUPPORT BRACKET BOLTS
  3. Tighten support bracket bolts (3) and nut (2). See Fig 2.
  4. Connect field terminal connector at rear of generator.
  5. Install battery output cable and nut to B+ terminal at top of generator and tighten to 13 N.m (115 in. lbs.)
  6. Install protective plastic cover to B+ stud at top of generator.
    CAUTION: Never force a belt over a pulley rim using a screwdriver. The synthetic fiber of the belt can be damaged.
    CAUTION: When installing a serpentine accessory drive belt, the belt MUST be routed correctly. The water pump will be rotating in the wrong direction if the belt is installed incorrectly, causing the engine to overheat. Refer to belt routing label in engine compartment, or refer to BELT-ACCESSORY DRIVE .
  7. Install generator drive belt. Refer to COOLING for procedure.
  8. Install engine oil fill cap and engine oil dipstick.
  9. Install plastic decorative engine cover. Cover snaps onto engine.
  10. Connect negative battery cable.
  11. Check charging system for proper operation.