A/C APPLICATION SPECIFICATIONS
| Item | Description | Notes |
|---|---|---|
| Vehicle | KJ- Liberty | .... |
| System | R134aw/fixed orifice tube | .... |
| Compressor | Sanden SD-7 | SP-15 PAG oil |
| Freeze-up Control | A/C low pressure switch | accumulator mounted |
| Low psi Control | opens < 25 psi - resets > 43 psi | .... |
| High psi Control | switch - opens > 450-490 psi -resets < 270-330 psi | discharge line |
| Control Head | manual type | .... |
| Mode Door | vacuum | .... |
| Blend Door | electric | .... |
| Recirculation Door | vacuum | .... |
| Blower Motor | hard wired to control head | resistor block |
| Cooling Fan | viscous for cooling, single speed electric for A/C | .... |
| Clutch | Electromechanical | .... |
| Control | relay | PCM |
| Draw | 2 - 3.7 amps @ 12V | +/- 0.5V @ 70°F |
| Gap | 0.01 6" -0.031" | .... |
| DRB III® | .... | .... |
| Reads | IPS, RPM, A/C switch test | .... |
| Actuators | clutch and fan relay | .... |