STARTER SERVICE SPECIFICATIONS
Application
Specification
Cranking Test
Test Voltage
12 Volts
Minimum Voltage
7.8 Volts
Amperage Draw
160 Amps
No-Load Test @ 11.2 Volts
Maximum Amps
90 Amps
Minimum RPM
2400 RPM