DTC P0601: Internal Controller Failure
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION
. For circuit identification and wiring diagram, see WRANGLER
wiring diagram in WIRING DIAGRAMS article.
NOTE:
DTC P0601: INTERNAL CONTROLLER FAILURE is monitored with ignition on. DTC may be stored in Powertrain Control Module (PCM) if PCM senses internal checksum for software failed, does not match calculated value. Possible cause is: defective PCM.
Turn ignition on, with engine off. Using scan tool, read DTCs. If DTC P0601: INTERNAL CONTROLLER FAILURE is present, replace PCM. Perform TEST VER-2A. If DTC P0601: INTERNAL CONTROLLER FAILURE is not present, test is complete.