Controller Anti-Lock Brake (Cab)
- Remove pump motor connector from the CAB. Remove CAB mounting screws from the HCU. See Fig 1 . Remove CAB from the HCU.
- Install the CAB onto the HCU. Install the CAB mounting screws and tighten to 1.8 N.m (16 INCH lbs.). Install pump motor connector to the CAB.