Power Mirror Switch
Remove power mirror switch. See POWER MIRROR SWITCH under REMOVAL & INSTALLATION. Place selector switch in right or left mirror mode. Using ohmmeter, check for resistance at appropriate terminals when each of the operation switchs is activated. See Fig 1 and Fig 2 and see POWER MIRROR SWITCH CONTINUITY TEST . If continuity is not as specified, power mirror switch must be replaced as an assembly.
POWER MIRROR SWITCH CONTINUITY TEST
| Switch Position | Pin Continuity | |
|---|---|---|
| Left Mirror | ||
| Up | 6 & 8; 5, 1 & 4 | |
| Down | 6 & 1; 5 & 8 | |
| Right | 6 & 1; 5 & 4 | |
| Left | 6 & 4; 5, 1 & 8 | |
| Right Mirror | ||
| Up | 6 & 7; 5, 1 & 3 | |
| Down | 6 & 1; 5 & 7 | |
| Right | 6 & 1; 5 & 3 | |
| Left | 6 & 3; 5, 1 & 7 | |