Test 13A - Repairing Door Ajar Warning Light
- Ensure all doors and liftgate are adjusted and aligned. Close all doors. Using DRB, read left front door ajar switch status. If DRB displays CIRCUIT CLOSED, go to TEST 40A . If DRB does not display CIRCUIT CLOSED, open left front door. If DRB does not display CIRCUIT CLOSED, go to TEST 40A . If DRB displays CIRCUIT CLOSED, go to next step.
- Using DRB, read right front door ajar switch status. If DRB displays CIRCUIT CLOSED, go to TEST 41A . If DRB does not display CIRCUIT CLOSED, open right front door. If DRB does not display CIRCUIT CLOSED, go to TEST 41A . If DRB displays CIRCUIT CLOSED, go to next step.
- Using DRB, read side door ajar switch status. If DRB displays CIRCUIT CLOSED, go to TEST 42A . If DRB does not display CIRCUIT CLOSED, go to TEST 42A to diagnose a short in side door ajar circuit.