Test 11A - Repairing Liftgate Latch Sense Circuit
NOTE:
For connector terminal identification, refer to CONNECTOR IDENTIFICATION
. For wiring diagrams, see WIRING DIAGRAM
.
NOTE:
Perform TEST 1A
before proceeding with TEST 11A.
- Ensure liftgate is closed. Using DRB, read DOOR AJAR status. If DRB displays CLOSED, go to TEST 9A . If DRB does not display CLOSED, open liftgate and disconnect liftgate latch switch connector. Inspect connector, clean and repair as needed and go to next step.
- Using DRB in ohmmeter mode, check resistance of latch switch ground circuit (Black wire). If resistance is more than 5 ohms, repair open latch switch ground circuit (Black wire). Perform TEST VER-1 . If resistance is less than 5 ohms, go to next step.
- Connect a jumper wire between liftgate latch switch connector terminals No. 2 (Tan/Black wire) and No. 3 (Black wire). Using DRB, read DOOR AJAR status. If DRB displays CLOSED, replace liftgate latch switch. Perform TEST VER-1 . If DRB does not display CLOSED, locate VTA module connector and go to next step. See VEHICLE THEFT ALARM MODULE under REMOVAL & INSTALLATION.
- Without disconnecting VTA module connector, using a jumper wire backprobe VTA module connector terminal No. 1 (Tan/Black wire) to ground. Using DRB, read DOOR AJAR switch status. If DRB displays CLOSED, repair open liftgate latch sense circuit (Tan/Black wire). Perform TEST VER-1 . If DRB does not display CLOSED, replace VTA module. Perform TEST VER-1 .