LEMON Manuals: Even more car manuals for everyone
Home >> Jeep >> 1994 >> Cherokee Country, 4D Utility, RWD >> Repair and Diagnosis >> Electrical >> Starter >> Starter Specifications

Starter Specifications

BOSCH STARTER SPECIFICATIONS

Application Specification
Cranking Test
Test Voltage 12.5 Volts
Minimum Voltage 9.6 Volts
Amps 160 Amps
No-Load Test @ 11.5 Volts
Maximum Amps 75 Amps
Minimum RPM 2900 RPM
Solenoid Hold-In Test
Winding Voltage 3.5 Volts (Min.)
Solenoid Pull-In Test
Winding Voltage 6-7.5 Volts
MITSUBISHI STARTER SPECIFICATIONS

Application Specification
Cranking Test
Test Voltage 12.5 Volts
Minimum Voltage 9.6 Volts
Amps 130
No-Load Test @ 11.5 Volts
Maximum Amps 80 Amps
Minimum RPM 2500 RPM
Solenoid Hold-In Test
Winding Voltage 3.5 Volts (Min.)
Solenoid Pull-In Test
Winding Voltage 7.8 Volts (Max.)