Float Level
Invert air horn assembly, with gasket in place, and measure distance between float and air horn gasket (see Figure). Adjust to specification by bending float tab which contacts head of fuel inlet needle.
Invert air horn assembly, with gasket in place, and measure distance between float and air horn gasket (see Figure). Adjust to specification by bending float tab which contacts head of fuel inlet needle.