DTC B1300-11: Video Output "A" - Circuit short to ground: Action
- Refer to the applicable SYSTEM WIRING DIAGRAM(S) and check the low voltage differential signalling positive circuit for short circuit to ground
- Refer to the applicable SYSTEM WIRING DIAGRAM(S) and check the low voltage differential signalling negative circuit for short circuit to ground