DTC B13D1-11: Right Daytime Running Lamp And Position Lamp Power Feed - Circuit short to ground: Action
- Refer to the applicable system wiring diagram(s) and check the right side daytime running lamp and position lamp power supply circuit - Circuit reference RH_POS_DRL_PWR - For short circuit to ground. Repair wiring harness as required, clear the DTC and retest the system
- If no wiring faults are present, check and install new lamp LED array as required. Clear DTC and retest