LEMON Manuals: Even more car manuals for everyone
Home >> Jaguar >> 2008 >> XK8 2D Convertible >> Repair and Diagnosis >> Engine Performance >> System >> On Board Diagnostics >> Onboard Monitoring >> 4.3 Evaporative Emission System Monitoring >> 4.3.2 Description

4.3.2 Description

The evaporative emission monitoring system permits the detection of leaks with a diameter of 0.5 mm (20 thou of an inch) or greater. This is achieved by means of a pressure test of the system, performed by the Diagnostic Module - Tank Leakage (DMTL), which is an electrically operated pump fitted to the atmospheric air intake of the EVAP canister.

The test proceeds in 2 stages:

Fault Conditions That Can Be Identified