Selector Lever Cable and Bracket - Removal and Installation: Installation
- Install the selector cable and bracket.
- Connect the recovery line to the transmission selector cable.
- Install the bolts and tighten to 10 Nm (7 lb.ft).
- Connect the selector cable ball joint.
- Install the LH side transmission casing heat shield.
- Install the bolts and tighten to 10 Nm (7 lb.ft).
- Install the exhaust heat shield.
- Install the bolts and tighten to 10 Nm (7 lb.ft).
- Install the transmission selector cable gaiter.
- Disconnect the recovery line.
- Install the floor console. Refer to Floor Console article.