4.24.1 Description
During ignition on conditions, the voltages from the two-track accelerator pedal position sensor are monitored. Each track is independently monitored for out of range high and low conditions.
If the input voltage to the ECM stays above a defined value for longer than a calibratable period, the high input failure judgment is made. If the input voltage to the ECM stays below a defined value for longer than a calibratable period, the low input failure judgment is made.
Additionally the signals from the two tracks are compared. If the angle obtained from sensor 1 differs from the angle obtained from sensor 2 by more than a defined amount for longer than a calibration period a range/performance failure judgment is made.