DTC P0790: Mode Switch Circuit Malfunction
POSSIBLE SOURCE(S):
- Mode switch to TCM circuits open, shorted or high resistance.
- Mode switch failure.
ACTION(S) TO TAKE:
- Check operation of mode switch.
- Check mode switch circuit for open, short or high resistance. See WIRING DIAGRAMS .