Symptom #5
WARNING: This page is about a different car, the 2002 Jaguar XKR and 2002 Jaguar XK8. However, it is still accessible from the selected car via links, so may be relevant.
Insufficient heating
Possible Source(s):
- Coolant flow valve stuck 'closed'
- Coolant flow valve stuck 'open' allowing recirculation of coolant at engine idle
Action(s) to take:
- Renew valve
Possible Source(s):
- Motorized in-car aspirator seized
Action(s) to take:
- Renew aspirator
Possible Source(s):
- Cool air bypass damper stuck open
Action(s) to take:
- Renew check fault code#43
Possible Source(s):
- Blocked speed low
Action(s) to take:
- Check / clean / renew
Possible Source(s):
- Blower speed low
Action(s) to take:
- Check performance range
Possible Source(s):
- Low coolant level
Action(s) to take:
- Adjust as required (verify and correct reason for loss)
Possible Source(s):
- Engine thermostat faulty
Action(s) to take:
- Check engine running temperature
Possible Source(s):
- Heater water pump seized
Action(s) to take:
- Check Operation
Possible Source(s):
- Heater matrix blocked
Action(s) to take:
- Renew matrix
Possible Source(s):
- Heater circuit air-lock
Action(s) to take:
- Refer to COOLING SYSTEM DRAINING, FILLING AND BLEEDING - VEHICLES WITHOUT: SUPERCHARGER or COOLING SYSTEM DRAINING, FILLING AND BLEEDING - VEHICLES WITH: SUPERCHARGER for fill / bleed procedure.