STARTER COLD CRANKING SPECIFICATIONS

Application Specification
Test Voltage 12 Volts
Minimum Voltage 9 Volts
Amps 90 Amps
Minimum RPM 1500 RPM
Solenoid Hold-In Winding Voltage 4 Volts (Min.)
Solenoid Pull-In Winding Voltage 7 Volts