Battery Terminal Under Load Test

To check battery terminal voltage under load, connect voltmeter across battery terminals and operate starter. See Fig 1. Voltmeter should read about 10 volts. A voltage reading of less than 10 volts indicates excessive current flow in circuit. Remove starter for bench testing. See BENCH TESTING .

Fig 1: Testing Battery Terminal Voltage Under Load
G92C00531Courtesy of JAGUAR CARS, INC.