Battery Connections Test

Turn ignition off. Connect voltmeter positive lead to output terminal "B+". Ground negative lead and note reading. Connect voltmeter positive lead to battery positive terminal and negative lead to battery negative terminal. Both readings should be equal. If not, check for broken wires, faulty connections, or corroded terminals.