Adapter Case Valve Body: Disassembly
- Remove 11 mm bolt from valve body.
- Remove converter control solenoid assembly (1).
- Remove 11 mm bolt and retainer (2) from valve body.
- Remove force motor solenoid (3).
- Remove retainer (4), plug (5), 3/4 accumulator valve (6), and 3/4 accumulator control valve (7)
- Remove spring (8), retaining ring (9), and feed limit valve (10).
- Remove plug retainer (11), O-ring (12), plug (13), and force motor screen assembly (14).
- Use 5 mm bolt to pull plug.