LEMON Manuals: Even more car manuals for everyone
Home >> Isuzu >> 2003 >> Axiom Base, RWD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Self-Diagnostics >> Diagnostic Tests >> DTC P0125: Engine Coolant Temperature Sensor Excessive Time To Closed Loop Fuel Control >> Circuit Description

Circuit Description

To provide best possible combination of driveability, fuel economy and emission control, a closed loop air/fuel metering system is used. When the vehicle is first started, PCM controls fuel delivery in open loop, ignoring H02S signals and calculates air/fuel mixture ratio based on inputs from the ECT, TPS, and MAF sensors. PCM will begin using Bank 1 HO2S No. 1 and Bank 2 HO2S No. 1 signals to control fuel delivery under closed loop conditions when following have been met: