Diagnostic Aids
Check for poor connection at PCM. Inspect harness connectors for backed-out terminals, improper mating, broken locks, improperly formed or damaged terminals and poor terminal connection. Observe a voltmeter connected to 58X CKP sensor reference circuit at PCM harness connector while moving all related harnesses and connectors. A change in voltage indicates fault location. If DTC cannot be duplicated, check scan tool FAILURE RECORDS to determine mileage since last DTC was set.