Open Loop
When engine is cold, PCM ignores signal from heated oxygen sensor (HO2S). Air/fuel ratio is calculated based on inputs from TPS, ECT and MAF sensors. System will remain in open loop until HO2S reaches operating temperature, coolant temperature reaches preset temperature, a specific period of time has elapsed after engine starts and engine speed has been greater than a specified RPM since start-up.