Power Mirror Motor Circuit
Test power mirror motor circuit at control switch connector (harness side) by applying battery voltage to appropriate connector terminal and ground appropriate connector terminal. SeeFigure . See the POWER MIRROR MOTOR CIRCUIT TEST . If power mirror motor does not operate in all positions, check circuits and repair as necessary. If circuits are okay, replace appropriate mirror.
POWER MIRROR MOTOR CIRCUIT TEST (1)
| Switch Position | Apply 12 Volts To Term. No. | Ground Term. No. | |||
|---|---|---|---|---|---|
| Left Side | |||||
| UP | 4 | 3 | |||
| DOWN | 3 | 4 | |||
| LEFT | 1 | 3 | |||
| RIGHT | 3 | 1 | |||
| Right Side | |||||
| UP | 5 | 3 | |||
| DOWN | 3 | 5 | |||
| LEFT | 2 | 3 | |||
| RIGHT | 3 | 2 | |||
|
|||||