LEMON Manuals: Even more car manuals for everyone
Home >> Isuzu >> 1991 >> Rodeo LS, RWD, Standard >> Repair and Diagnosis >> Engine Performance >> Remove, Overhaul & Install >> Engine Controls - Remove/Install/Overhaul >> Fuel System (CARBURETED) >> Adjustments >> Choke Valve Opening Adjustment

Choke Valve Opening Adjustment

Position fast idle adjusting screw tip against fast idle cam second step. See Fig 1. Measure clearance between choke valve and choke valve chamber wall. Clearance should be.031-.051" (.80-1.30 mm). Choke valve angle should be 30 degrees. If clearance is not as specified, bend counter lever tang.

Fig 1: Adjusting Choke Valve Opening
G93359Courtesy of ISUZU MOTOR CO.