LEMON Manuals: Even more car manuals for everyone
Home >> International >> 1978 >> Scout II 2D Utility, 3.2L Eng, RWD, Automatic Trans, Diesel >> Repair and Diagnosis >> Electrical >> Charging Systems >> HITACHI Alternators >> Testing >> Field Attraction Check

Field Attraction Check

To measure the current flowing through field, connect an ammeter into the circuit (see  Fig 1 ).  A reading of approximately 2.4 amperes should be noted.

Fig 1: Measuring The Field Current
G09347003Courtesy of NOT AVAILABLE