Diagnosis Procedure
- PERFORM INITIALIZATION PROCEDURE
- Initialization procedure is performed and operation is confirmed. Refer to Work Procedure .
Is the inspection result normal?
YES>>
Inspection End.
NO>>
GO TO 2.
- CHECK FRONT LH ENCODER CIRCUIT
- Check front LH encoder circuit. Refer to Component Function Check .
Is the inspection result normal?
YES>>
GO TO 3.
NO>>
Repair or replace the malfunctioning parts.
- CONFIRM THE OPERATION
- Confirm the operation again.
Is the inspection result normal?
YES>>
Check intermittent incident. Refer to Intermittent Incident .
NO>>
GO TO 1.