LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2021 >> Q60 Pure, AWD >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Engine Control System (Diagnostics) (3 Of 4) >> Component Parts/Circuit Diagnosis >> Heated Oxygen Sensor 2 >> Component Inspection

Component Inspection

  1. INSPECTION START 

    Do you have CONSULT?

    YES

    GO TO 2.

    NO

    GO TO 3.

  2. CHECK HEATED OXYGEN SENSOR 2 

    SYMBOL With CONSULT

    1. Turn ignition switch ON.
    2. On CONSULT screen, select "ENGINE">>"Data Monitor".
    3. Start engine and warm it up to the normal operating temperature.
    4. Turn ignition switch OFF and wait at least 10 seconds.
    5. Start engine and keep the engine speed between 3, 500 and 4, 000 rpm for at least 1 minute under no load.
    6. Let engine idle for 1 minute.
    7. On CONSULT screen, select "ENGINE">>"Active Test">>"FUEL INJECTION"
    8. Check "HO2S2 (B1)/(B2)" at idle speed when adjusting "FUEL INJECTION" to +/-25%.
      GNSJSBIA3451Z-451Courtesy of NISSAN NORTH AMERICA, INC.

      "HO2S2 (B1)/(B2)" should be above SYMBOL 0.74 V at least once when the "FUEL INJECTION" is +25%.

      "HO2S2 (B1)/(B2)" should be below SYMBOL 0.18 V at least once when the "FUEL INJECTION" is -25%.

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    Replace malfunctioning heated oxygen sensor 2. Refer to CATALYST : Removal & Installation .

  3. CHECK HEATED OXYGEN SENSOR 2-I 

    SYMBOL Without CONSULT

    1. Start engine and warm it up to the normal operating temperature.
    2. Turn ignition switch OFF and wait at least 10 seconds.
    3. Start engine and keep the engine speed between 3, 500 and 4, 000 rpm for at least 1 minute under no load.
    4. Let engine idle for 1 minute.
    5. Check the voltage between ECM harness connector terminals under the following condition.

      ECM

      Condition

      Voltage

      Connector

      +

      -

      Terminal

      F143

      49

      [HO2S2 (bank 1)]

      81

      Revving up to 4, 000 rpm under no load at least 10 times

      The voltage should be above 0.74 V at least once during this procedure.

      The voltage should be below 0.18 V at least once during this procedure.

      51

      [HO2S2 (bank 2)]

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    GO TO 4.

  4. CHECK HEATED OXYGEN SENSOR 2-II 

    Check the voltage between ECM harness connector terminals under the following condition.

    ECM

    Condition

    Voltage

    Connector

    +

    -

    Terminal

    F143

    49

    [HO2S2 (bank 1)]

    81

    Keeping engine at idle for 10 minutes

    The voltage should be above 0.74 V at least once during this procedure.

    The voltage should be below 0.18 V at least once during this procedure.

    51

    [HO2S2 (bank 2)]

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    GO TO 5.

  5. CHECK HEATED OXYGEN SENSOR 2-III 

    Check the voltage between ECM harness connector terminals under the following condition.

    ECM

    Condition

    Voltage

    Connector

    +

    -

    Terminal

    F143

    49

    [HO2S2 (bank 1)]

    81

    Coasting from 80 km/h (50 MPH) in D position

    The voltage should be above 0.74 V at least once during this procedure.

    The voltage should be below 0.18 V at least once during this procedure.

    51

    [HO2S2 (bank 2)]

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    Replace malfunctioning heated oxygen sensor 2. Refer to CATALYST : Removal & Installation .