Component Inspection
- CHECK EVAP CANISTER VENT CONTROL VALVE-I
- Turn ignition switch OFF.
- Remove EVAP canister vent control valve from EVAP canister. Refer to EVAP CANISTER : Exploded View .
- Check portion
of EVAP canister vent control valve for rust.
Is it rusted?
YES
Replace EVAP canister vent control valve. Refer to EVAP CANISTER : Exploded View .
NO
GO TO 2.
- CHECK EVAP CANISTER VENT CONTROL VALVE-II
With CONSULT
- Reconnect harness connectors disconnected.
- Turn ignition switch ON.
- On CONSULT screen, select "ENGINE">>"Active Test">>"VENT CONTROL/V".
- Check air passage continuity and operation delay time.
Make sure that new O-ring is installed properly.
Condition VENT CONT/V
Air passage continuity between
and
ON
Not existed
OFF
Existed
Operation takes less than 1 second.
Without CONSULT
- Disconnect EVAP canister vent control valve harness connector.
- Check air passage continuity and operation delay time under the following conditions.
Make sure that new O-ring is installed properly.
Condition
Air passage continuity between
and
12 V direct current supply between terminals 1 and 2
Not existed
OFF
Existed
Operation takes less than 1 second.
Is the inspection result normal?
YES
GO TO 3.
NO
Replace EVAP canister vent control valve. Refer to EVAP CANISTER : Exploded View .
- CHECK EVAP CANISTER VENT CONTROL VALVE-III
With CONSULT
- Clean the air passage [portion
to
] of EVAP canister vent control valve using an air blower.
- On CONSULT screen, select "ENGINE">>"Active Test">>"VENT CONTROL/V".
- Check air passage continuity and operation delay time.
Make sure that new O-ring is installed properly.
Condition VENT CONT/V
Air passage continuity between
and
ON
Not existed
OFF
Existed
Operation takes less than 1 second.
Without CONSULT
- Clean the air passage [portion
to
] of EVAP canister vent control valve using an air blower.
- Check air passage continuity and operation delay time under the following conditions.
Make sure that new O-ring is installed properly.
Condition
Air passage continuity between
and
12 V direct current supply between terminals 1 and 2
Not existed
OFF
Existed
Operation takes less than 1 second.
Is the inspection result normal?
YES
INSPECTION END
NO
Replace EVAP canister vent control valve. Refer to EVAP CANISTER : Exploded View .
- Clean the air passage [portion