Diagnosis Procedure
- CHECK BRAKE PEDAL POSITION SWITCH POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect brake pedal position switch harness connector.
- Turn ignition switch ON.
- Check the voltage between brake pedal position switch harness connector and ground.
+
-
Voltage
Brake pedal position switch
Connector
Terminal
E44
1
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 2.
- CHECK BRAKE PEDAL POSITION SWITCH POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect fuse block (J/B) harness connector.
- Check the continuity between brake pedal position switch harness connector and fuse block (J/B) harness connector.
Brake pedal position switch
Fuse block (J/B)
Continuity
Connector
Terminal
Connector
Terminal
E44
1
E65
11F
Existed
- Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace error-detected parts.
- CHECK FUSE
- Disconnect 10A fuse (No. 12) from fuse block (J/B).
- Check that 10A fuse is not blowning.
Is the fuse blown (open)?
YES
Replace the fuse after repairing the applicable circuit.
NO
Perform trouble diagnosis for power supply circuit.
- CHECK BRAKE PEDAL POSITION SWITCH INPUT SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between brake pedal position switch harness connector and ECM harness connector.
Brake pedal position switch
ECM
Continuity
Connector
Terminal
Connector
Terminal
E44
2
E152
192
Existed
- Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO 5.
NO
Repair or replace error-detected parts.
- CHECK BRAKE PEDAL POSITION SWITCH
Refer to Component Inspection .
Is the inspection result normal?
YES
Check intermittent incident. Refer to Inspection .
NO
Replace brake pedal position switch. Refer to BRAKE PEDAL : Exploded View .