Diagnosis Procedure
- CHECK SELF DIAGNOSTIC RESULT
- Turn ignition switch ON.
- Check DTC using CONSULT.
What is the display history of DTC "B210A-00"?
"PAST"
GO TO 2.
"CRNT"
GO TO 3.
- ERASE DTC
- Select "Self Diagnostic Result" mode of "Steering column cont module" using CONSULT.
- Erase DTC, and then repeat "DTC CONFIRMATION PROCEDURE". Refer to DTC Description .
Is DTC "B210A-00" detected?
YES
GO TO 3.
NO
Check intermittent incident. Refer to Intermittent Incident .
- CHECK BATTERY VOLTAGE
- Turn ignition switch OFF.
- Check battery voltage is more than 9 V and less than 16 V.
Is the inspection result normal?
YES
GO TO 4.
NO
Perform battery inspection. Refer to Work Procedure .
- CHECK ALTERNATOR
Perform alternator diagnosis and repair work flow. Refer to Work Flow (With EXP-800 NI or GR8-1200 NI) or Work Flow (Without EXP-800 NI or GR8-1200 NI) .
Is the inspection result normal?
YES
GO TO 5.
NO
Repair as needed.
- CHECK FUSE
Check that the following fuse is not blown (open).
Signal name
Fuse No.
Battery power supply
32 (5 A)
56 (10 A)
Is the fuse (open)?
YES
Replace the blown (open) fuse after repairing the affected circuit if a fuse is blown.
NO
GO TO 6.
- CHECK STEERING COLUMN CONTROL MODULE POWER SUPPLY CIRCUIT
- Disconnect steering column control module connector and fuse and fusible link block 2 connector.
- Check continuity between steering column control module harness connector and fuse and fusible link block 2 harness connector.
Steering column control module
Fuse and fusible link block 2
Continuity
Connector
Terminal
Connector
Terminal
M3
4
M107
8
Existed
6
M119
46
- Check continuity between steering column control module harness connector and ground.
Steering column control module
--
Continuity
Connector
Terminal
M3
4
Ground
Not existed
6
Is the inspection result normal?
YES
GO TO 7.
NO
Repair or replace harness.
- CHECK STEERING COLUMN CONTROL MODULE GROUND CIRCUIT
Check continuity between steering column control module harness connector and ground.
Steering column control module
--
Continuity
Connector
Terminal
M3
3
Ground
Existed
7
Is the inspection result normal?
YES
Replace steering column control module. Refer to Removal and Installation .
NO
Repair or replace harness.