LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2017 >> QX30 Base >> Repair and Diagnosis >> Steering >> Steering Control Systems >> Steering Control System (DTC/Circuit Diagnosis) >> DTC/Circuit Diagnosis >> Power Supply And Ground Circuit >> Diagnosis Procedure >> Diagnostic Test

Diagnostic Test

  1. .CHECK EPS CONTROL UNIT POWER SUPPLY

    1. Turn the ignition switch OFF.
    2. Disconnect EPS control unit harness connector.
    3. Check the voltage between the EPS control unit harness connector and ground.
      Terminals Voltage
      (+) (-)
      EPS control unit Ground
      Connector Terminal
      E45 3 - Battery voltage

    Is the inspection result normal?

    YES 

    GO TO STEP 3  .

    NO 

    GO TO STEP 2  .

  2. .CHECK EPS CONTROL UNIT POWER SUPPLY CIRCUIT

    1. Check the 100A fusible link (#B).
    2. Disconnect fuse box harness connector.
    3. Check the continuity between EPS control unit harness connector and fuse box harness connector.
      EPS control unit Fuse box Continuity
      Connector Terminal Connector Terminal
      E45 3 E74 3 Existed
    4. Check the continuity between EPS control unit harness connector and ground.
      EPS control unit Ground Continuity
      Connector Terminal
      E45 3 - Not existed

    Is the inspection result normal?

    YES 

    Perform trouble diagnosis for battery power supply. Refer to WIRING DIAGRAM - BATTERY POWER SUPPLY - .

    NO 

    Repair or replace error-detected parts.

  3. CHECK EPS CONTROL UNIT GROUND CIRCUIT

    Check the continuity between EPS control unit harness connector and ground.

    EPS control unit Ground Continuity
    Connector Terminal
    E45 4 - Existed

    Is the inspection result normal?

    YES 

    GO TO STEP 4  .

    NO 

    Repair or replace error-detected parts.

  4. CHECK TERMINAL

    1. Check the EPS control unit pin terminals for damage or loose connection with harness connector.
    2. Check the fuse box pin terminals for damage or loose connection with harness connector.

    Is the inspection result normal?

    YES 

    INSPECTION END

    NO 

    Repair or replace error-detected parts.