Diagnostic Test
- CHECK QUANTITY CONTROL VALVE-1
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the resistance between ECM harness connector terminals.
ECM Resistance (Ω) + - Terminal 75 76 0.3 - 1.1
Is the inspection result normal?
YES
INSPECTION END
NO
GO TO STEP 2 .
- CHECK QUANTITY CONTROL VALVE-2
- Disconnect quantity control valve harness connector.
- Check the resistance between quantity control valve terminals.
Quantity control valve Resistance (Ω) + - Terminal 1 2 0.3 - 1.1
Is the inspection result normal?
YES
INSPECTION END
NO
Replace high pressure fuel pump. Refer to REMOVAL AND INSTALLATION .