Transfer Fluid: Refilling
- Remove filler plug (1). Fill up with new transfer fluid up to mounting hole for the filler plug.
Fluid grade and Viscosity : Refer to FLUIDS AND LUBRICANTS . Fluid capacity : Refer to GENERAL SPECIFICATIONS . CAUTION:Carefully fill the fluid. (Fill up for approximately 3 minutes.)
- Leave the vehicle for 3 minutes, and check the fluid level again.
- Set a new gasket onto filler plug, and install it on transfer and tighten to the specified torque.
Specified torque : 48 N•m (4.9 kg - m, 35 ft - lb) CAUTION:Never reuse gasket.
- Perform learning of transfer fluid viscosity. Refer to WORK PROCEDURE .