Diagnosis Procedure
- CHECK SECURITY INDICATOR LAMP POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector.
- Check voltage between combination meter harness connector and ground.
(+) (-) Voltage (V)
(Approx.)Combination meter Connector Terminal M53 1 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Check the following.
- 10A fuse [No. 6, located in the fuse block (J/B)]
- Harness for open or short between combination meter and fuse.
- If NG, repair or replace fuse or harness.
- CHECK COMBINATION METER CIRCUIT
- Disconnect BCM connector.
- Check continuity between combination meter harness connector and BCM harness connector.
Combination meter BCM Continuity Connector Terminal Connector Terminal M53 10 M123 141 Existed - Check continuity between combination meter harness connector and ground.
Combination Meter Ground Continuity Connector Terminal M53 10 Not existed
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace harness.
- CHECK SECURITY INDICATOR LAMP
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Replace combination meter. Refer to REMOVAL AND INSTALLATION .