Component Inspection (Shift Lock Solenoid)
- CHECK SHIFT LOCK SOLENOID
Apply voltage to terminals 3 and 4 of shift lock unit connector, and then check that shift lock solenoid is activated.
CAUTION: Connect the fuse between the terminals when applying the voltage.Shift lock unit connector Condition Status Terminal + (fuse) - 3 4 Apply 12 V direct current between terminals 3 and 4. Shift lock solenoid operates Can the lock plate be moved up and down?
YES: INSPECTION END
NO: Replace shift lock unit. Refer to "REMOVAL AND INSTALLATION ".