LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2013 >> EX37 Base, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 38 (Power Control System) >> Power Distribution System >> Component Diagnosis >> DTC B2615: Blower Relay Circuit >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2008 Infiniti EX35. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK BLOWER RELAY POWER SUPPLY 
    1. Turn ignition switch OFF.
    2. Disconnect blower relay.
    3. Check voltage between blower relay harness connector and ground.
      TERMINALS VOLTAGE REFERENCE

      (+) (-) Condition Voltage (V) (Approx.)
      Blower relay
      Terminal
      1 Ground Ignition switch OFF or ACC 0
      ON Battery voltage

    Is the inspection result normal? 

    YES: GO TO  3.

    NO: GO TO  2.

  2. CHECK BLOWER RELAY POWER SUPPLY CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect BCM connector.
    3. Check continuity between blower relay harness connector and BCM harness connector.
      TERMINALS CONTINUITY REFERENCE

      Blower relay BCM Continuity
      Terminal Connector Terminal
      1 M122 102 Existed
    4. Check continuity between blower relay harness connector and ground.
      TERMINALS CONTINUITY REFERENCE

      Blower relay Ground Continuity
      Terminal
      1 Not existed

    Is the inspection result normal? 

    YES: Replace BCM. Refer to REMOVAL AND INSTALLATION .

    NO: Repair or replace harness or connector.

  3. CHECK BLOWER RELAY GROUND CIRCUIT 
    1. Turn ignition switch OFF.
    2. Check continuity between blower relay harness connector and ground.
      TERMINALS CONTINUITY REFERENCE

      Blower relay Ground Continuity
      Terminal
      2 Existed

    Is the inspection result normal? 

    YES: GO TO  4.

    NO: Repair blower relay ground circuit.

  4. CHECK BLOWER RELAY 

    Refer to COMPONENT INSPECTION  .

    Is the inspection result normal? 

    YES: GO TO  5.

    NO: Replace blower relay.

  5. CHECK INTERMITTENT INCIDENT 

    Refer to INTERMITTENT INCIDENT .

    INSPECTION END